Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2017, 07:44 AM
  • 08 0012_08 0012_7112017_024013.mp4

Date
07/11/2017
W/O
0649897
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00016
PipeID
P00012
Time
12:44 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0587
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20170711VMR_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0012
Downstream MH
08 0012
Dir. of Survey
Upstream
Length Surveyed
7.9 ft.
Total Length
7.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 08 0012 to 08 0012
MH: 08 0012MH: 08 0012upstream0 ft. AMH - Downstream Manhole, Survey Ends - 03:18 AM5.7 ft. TF - Tap Factory Made, at 08 o'clock, -, within 8 inches of joint: NO, 4" - 4 FT DOWN FROM RIM5.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4" - NEAR W/S CHANNEL7.7 ft. TFB - Tap Factory Made Abandoned, at 08 o'clock, -, within 8 inches of joint: NO, 4"7.9 ft. AMH - Upstream Manhole, Survey Begins - TOPSIDE INSPECTION7.9 ft. MGO - General Observation - BRICKS OFFSET

Observation photos (2)

  • General Observation - BRICKS OFFSET

    0 ft. - General Observation - BRICKS OFFSET

  • Tap Factory Made Abandoned, at 08 o'clock, -, within 8 inches of joint: NO, 4"

    0.2 ft. - Tap Factory Made Abandoned, at 08 o'clock, -, within 8 inches of joint: NO, 4"

Observations (6)

DistanceCodeObservation
0AMHTOPSIDE INSPECTION
0.2TFB
2TFNEAR W/S CHANNEL
2.2TF4 FT DOWN FROM RIM
0MGOBRICKS OFFSET
7.9AMH03:18 AM

Properties (4)

customer
LACSD
datetime
2017-07-11T00:44:48-07:00
documentation
REVELES,MANANES,OLIVERIII
is_lateral_inspection
false