Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 3, 2017, 07:25 PM
  • A 0815_A 0814_732017_124600.mp4

Date
07/03/2017
W/O
0636060
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z00325
PipeID
P08315
Time
12:25 PM
Certificate
PENDING
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7452
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
22
Purpose
Routine Assessment
Project
20170703MI_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
A 0814
Downstream MH
A 0815
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
4
O&M Quick
4200
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
18
Pipe schematic from manhole A 0814 to A 0815
MH: A 0814MH: A 0815upstream0 ft. MGO - General Observation - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES0 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. AMH - Downstream Manhole, Survey Begins - 12:50 PM2 ft. MWL - Water Level, 100 %of cross sectional area2 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. LU - Alignment Up, 45 %

Observation photos (4)

  • General Observation - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

    2 ft. - General Observation - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

  • Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

    2 ft. - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
2MGOVIEW OF THE UPLEG PIPE OF THE D/S SIPHON
0AMH12:50 PM
2MSAVIEW OF THE UPLEG PIPE OF THE D/S SIPHON
0MWL
0MWM
2SSS
2SAP
0LU
2SRV

Properties (6)

additional_info
VIEW OF THE UPLEG PIPE OF THE D/S SIPHON
custom_field_two
2
customer
LACSD
datetime
2017-07-03T12:25:00-07:00
documentation
IGNACIO, FRANKLIN, OBREGON
is_lateral_inspection
false