Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 27, 2019, 04:20 PM
  • Section#2_22 1063_22 1062__6272019__I0160.mp4

Date
06/27/2019
W/O
0779051
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00812
PipeID
P17434
Time
9:20 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0160
Sewer Name
22 IRWINDALE TRUNK, SECTS 2,3,4,&5
City
IRWINDALE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Maintenance Related
Project
20190627SHO_IRWINDALE_TRUNK_SECTS_2_3_4_5
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 1062
Downstream MH
22 1063
Dir. of Survey
Upstream
Length Surveyed
271.5 ft.
Total Length
271.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
2
Overall Quick
Overall Rating
20
Pipe schematic from manhole 22 1062 to 22 1063
MH: 22 1062MH: 22 1063upstream0 ft. MSA - Survey Abandoned - OBSTRUCTIONS FOUND217.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Finish246.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 11 to 01 o'clock, , within 8 inches of joint: YES260.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start271.5 ft. MWL - Water Level, 30 %of cross sectional area271.5 ft. AMH - Downstream Manhole, Survey Begins - MH 1063271.5 ft. MWM - Water Mark, 40 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 11 to 01 o'clock,  , within 8 inches of joint: YES

    25.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 11 to 01 o'clock, , within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
25.1DAGS
0MWL
0AMHMH 1063
0MWM
10.7DAGS
54.2DAGS
271.5MSAOBSTRUCTIONS FOUND

Properties (7)

additional_info
OBSTRUCTION INSP. ONLY
custom_field_three
OBSTRUCTION INSP. ONLY
custom_field_two
5
customer
LACSD
datetime
2019-06-27T09:20:13-07:00
documentation
OBREGON, YOUNG, IGNACIO
is_lateral_inspection
false