- Date
- 06/27/2019
- W/O
- 0772128
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00941
- PipeID
- P11141
- Time
- 3:25 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0159
- Sewer Name
- H JOINT OUTFALL H - UNIT 9B
- City
- INDUSTRY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- 20190627MDM_JOINT_OUTFALL_H_UNIT_9H
- Material
- NRCP
- Shape
- Circular
- Height
- 28 in.
- Upstream MH
- H 0732
- Downstream MH
- H 0731
- Dir. of Survey
- Downstream
- Length Surveyed
- 724.7 ft.
- Total Length
- 724.7 ft.
- Structural Index
- 2
- Structural Quick
- 2\00
- Structural Rating
- 290
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 292
Pipe schematic from manhole H 0732 to H 0731 Observation photos (7)

0 ft. - General Observation - STEEL PLATED MH COVER

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

2 ft. - General Observation - MAG COAT 98% START

103.8 ft. - General Observation - 100% MAG COAT

140 ft. - Infiltration Weeper, from 08 to 04 o'clock, within 8 inches of joint: YES - POSSIBLE UNDER MAG COAT

313.3 ft. - Surface Spalling, from 09 to 11 o'clock, within 8 inches of joint: NO - SLIGHTLY FLAKING CONCRETE UNDER MAG COAT

448 ft. - General Observation - 100% MAG COAT