Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2019, 05:16 PM
  • H 0710_H 0709_6172019_101908.mp4

Date
06/17/2019
W/O
0772128
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00941
PipeID
P11117
Time
10:16 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1234
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WHITTIER
Loc. details
Yard
Location Code
Y
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
20190617_SHO_JOINT_OUTFALL_H_UNIT_9B
Material
NRCP
Shape
Circular
Height
25 in.
Upstream MH
H 0709
Downstream MH
H 0710
Dir. of Survey
Upstream
Length Surveyed
45.7 ft.
Total Length
45.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole H 0709 to H 0710
MH: H 0709MH: H 0710upstream0 ft. MGO - Reversal Inspection - COMPLETE0.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish43.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT43.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - GREASE/ENCRUSTATION AT 8 AND 443.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT45.7 ft. MWL - Water Level, 45 %of cross sectional area45.7 ft. MWM - Water Mark, 50 %of cross sectional area45.7 ft. AMH - Downstream Manhole, Survey Begins - H 0709

Observations (10)

DistanceCodeObservation
0MWL
45.7MGOCOMPLETE
45SSS
0MWM
0AMHH 0709
2SAVSLIGHT
45SAV
2DAEGREASE/ENCRUSTATION AT 8 AND 4
45DAE
2SSSSLIGHT

Properties (7)

additional_info
REVERSAL, ONLY NEED TO GO 40 FT TO COMPLETE INSPECTION
custom_field_three
SPALLING AND VISIBLE AGG.
custom_field_two
3
customer
LACSD
datetime
2019-06-17T10:16:55-07:00
documentation
OBREGON, YOUNG, IGNACIO
is_lateral_inspection
false