Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2016, 06:22 AM
  • 02 0720_02 0719A_20160726_004539.mp4

Date
07/25/2016
W/O
574316
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00294
PipeID
P03274
Time
11:22 PM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3662
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Routine Assessment
Project
WO_574316_TV02111_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0720
Downstream MH
02 0719A
Dir. of Survey
Downstream
Length Surveyed
321.1 ft.
Total Length
321.1 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole 02 0720 to 02 0719A
MH: 02 0720MH: 02 0719Adownstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 07205.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - wandering 30%6.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"9.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"71.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish89.6 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES95.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"98 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"98 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - wandering 30%220.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"222.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"275.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES314.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish321.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0719A

Observation photos (3)

  • Water Level, 35 %of cross sectional area

    0 ft. - Water Level, 35 %of cross sectional area

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    6.5 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    275.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
314.2FL
89.6FL
95.4TFA
0MWM
275.4CM
5.1FLwandering 30%
71.2FL
220.2TFA
0MWL
98TFC
6.5TFC
321.1AMH02 0719A
9.4TFC
222.8TF
0AMH02 0720
98FLwandering 30%

Properties (6)

additional_info
SC305541
custom_field_two
2
customer
LACSD
datetime
2016-07-25T23:22:47-07:00
documentation
PROPIPE
is_lateral_inspection
false