Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2016, 10:19 AM
  • 02 0749_02 0748_20160719_042309.mp4

Date
07/19/2016
W/O
574316
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00294
PipeID
P03305
Time
3:19 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3657
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_574316_TV02111_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0748
Downstream MH
02 0749
Dir. of Survey
Upstream
Length Surveyed
12.9 ft.
Total Length
12.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 02 0748 to 02 0749
MH: 02 0748MH: 02 0749upstream0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Ends - 02 074912.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE12.9 ft. MWL - Water Level, 5 %of cross sectional area12.9 ft. AMH - Downstream Manhole, Survey Begins - 02 074812.9 ft. MWM - Water Mark, 5 %of cross sectional area

Observation photos (1)

  • Vermin Cockroach

    12.9 ft. - Vermin Cockroach

Observations (6)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
0MWL
0AMH02 0748
12.9VC
0MWM
12.9AMH02 0749

Properties (6)

additional_info
SC305536
custom_field_two
4
customer
LACSD
datetime
2016-07-19T03:19:00-07:00
documentation
PROPIPE
is_lateral_inspection
false