Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2018, 08:42 AM
  • B 1536_B 1535_5212018_051347.mp4

Date
05/21/2018
W/O
070705
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01200
PipeID
P26346
Time
1:42 AM
Certificate
0-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0864
Sewer Name
B JOINT OUTFALL B - UNIT 6J RELIEF
City
LA CANADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
20180521MDM_JOINT_OUTFALL_B_UNIT_6J_RELIEF
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
B 1536
Downstream MH
B 1535
Dir. of Survey
Downstream
Length Surveyed
567.9 ft.
Total Length
567.9 ft.
Structural Index
2
Structural Quick
2700
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole B 1536 to B 1535
MH: B 1536MH: B 1535downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:10AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PIPE8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE107.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE114.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE201.4 ft. MGO - General Observation - 18" VCP SPORATIC BLISTERING284.8 ft. MGP - General Photograph298 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6", 6" - Active323.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE337.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE414.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN520.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE567.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERINNG PIP[E567.9 ft. AMH - Downstream Manhole, Survey Ends - 5:50AM

Observation photos (9)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PIPE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PIPE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    107.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    114.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

  • General Observation - 18" VCP SPORATIC BLISTERING

    201.4 ft. - General Observation - 18" VCP SPORATIC BLISTERING

  • General Photograph

    284.8 ft. - General Photograph

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    323.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    337.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

    520.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PIPE

Observations (16)

DistanceCodeObservation
114.2SSSBLISTERING PIPE
107.3SSSBLISTERING PIPE
323.5SSSBLISTERING PIPE
8SSSBLISTERING PIPE
0MWL
567.7SSSBLISTERINNG PIP[E
298TBActive
414.8TFOPEN
2SSSBLISTERING PIPE
520.8SSSBLISTERING PIPE
0MWM
337.3SSSBLISTERING PIPE
201.4MGO18" VCP SPORATIC BLISTERING
567.9AMH5:50AM
284.8MGP
0AMH5:10AM

Properties (6)

custom_field_three
BLISTERING VCP
custom_field_two
2
customer
LACSD
datetime
2018-05-21T01:42:47-07:00
documentation
MARTIN,REVELES,OLIVRE 111
is_lateral_inspection
false