Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 8, 2017, 07:00 PM
  • H 0338_H 0337_882017_121624.mp4

Date
08/08/2017
W/O
0646406
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00175
PipeID
P10788
Time
12:00 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7485
Sewer Name
H JOINT OUTFALL H - UNIT 4
City
PICO RIVERA
Loc. details
Yard
Location Code
Y
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
06
Purpose
Capital Improvement Program Assesment
Project
20170808SHO_JOINT_OUTFALL_H_UNIT_4
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
H 0338
Downstream MH
H 0337
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
17
Pipe schematic from manhole H 0338 to H 0337
MH: H 0338MH: H 0337downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12100 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MWL - Water Level, 55 %of cross sectional area2 ft. LD - Alignment Down, 45 %2 ft. SAP - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO2 ft. MSA - Survey Abandoned - VIEW OF THE DOWNLEG2 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO

Observation photos (3)

  • Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Survey Abandoned - VIEW OF THE DOWNLEG

    2 ft. - Survey Abandoned - VIEW OF THE DOWNLEG

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
2LD
2SAP
2MSAVIEW OF THE DOWNLEG
2SRC
0AMH1210
0MWM
0MWL

Properties (7)

additional_info
VIEW OF THE DOWNLEG OF THE SIPHON
custom_field_three
CORRODED REBAR & PROJECTING AGG.
custom_field_two
2
customer
LACSD
datetime
2017-08-08T12:00:00-07:00
documentation
OBREGON, FRANKLIN, BRAR
is_lateral_inspection
false