Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2017, 05:12 PM
Date
12/04/2017
W/O
0674132
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z01090
PipeID
P24674
Time
9:12 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6877
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
20171204DF_ALAMITOS_PP_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0773
Downstream MH
29 0774
Dir. of Survey
Upstream
Length Surveyed
124.6 ft.
Total Length
124.6 ft.
Structural Index
2
Structural Quick
3D2D
Structural Rating
121
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
121
Pipe schematic from manhole 29 0773 to 29 0774
MH: 29 0773MH: 29 0774upstream0 ft. MGO - General Observation - conn @ mh 3 o'clock/unknown0 ft. MGO - General Observation - conn @ mh 9 o'clock/active0 ft. AMH - Upstream Manhole, Survey Ends - 10:30 am1.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish29.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"32.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4" - unknown44.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4" - OPEN46.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4" - open65.6 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES86.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4" - unknown95 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"122.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start122.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start124.5 ft. MWM - Water Mark, 15 %of cross sectional area124.5 ft. MWL - Water Level, 10 %of cross sectional area124.6 ft. AMH - Downstream Manhole, Survey Begins - 9:18 AM

Observations (17)

DistanceCodeObservation
124.6MGOconn @ mh 3 o'clock/unknown
59CC
122.7CM
29.6TFC
92.5TFunknown
124.6MGOconn @ mh 9 o'clock/active
78TFopen
38.2TFunknown
94.9TFC
124.6AMH10:30 am
2CM
0.1MWM
0.1MWL
2SSS
80.3TFOPEN
0AMH9:18 AM
122.7SSS

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2017-12-04T09:12:36-08:00
is_lateral_inspection
false