Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 20, 2017, 08:15 AM
  • 22 0299_22 1351 _20012017_001625.mpg

Date
01/20/2017
W/O
613624
Weather
Light Rain
Operator/Surveyor
R.VARGAS
Sewer ID
Z00794
PipeID
P16586
Time
12:15 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4084
Sewer Name
22 CAMERON TRUNK, SECTION 4
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613624_TV22144_JAN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0299
Downstream MH
22 1351
Dir. of Survey
Downstream
Length Surveyed
305.5 ft.
Total Length
305.5 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
17
O&M Index
1
O&M Quick
2215
O&M Rating
9
Overall Index
2
Overall Quick
Overall Rating
26
Pipe schematic from manhole 22 0299 to 22 1351
MH: 22 0299MH: 22 1351downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02990 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. MMC - Material Change, Vitrified clay pipe2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES14.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"18.3 ft. CC - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES23.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"58.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"73.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"94.8 ft. CC - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES99 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES108.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"123.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"136.4 ft. FC - Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES162.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"173.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"211.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"226.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"244.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES250 ft. VC - Vermin Cockroach250 ft. MGP - General Photograph259.5 ft. RFJ - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES261.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"266.5 ft. RFJ - Roots Fine Joint, from 02 to 05 o'clock, within 8 inches of joint: YES276.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"285 ft. RFJ - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES301 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES301 ft. RFJ - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES302.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish305.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE305.5 ft. AMH - Downstream Manhole, Survey Ends - 22 1351

Observation photos (13)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    18.3 ft. - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    94.8 ft. - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    99 ft. - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES

    136.4 ft. - Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    244.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Photograph

    250 ft. - General Photograph

  • Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

    259.5 ft. - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 02 to 05 o'clock, within 8 inches of joint: YES

    266.5 ft. - Roots Fine Joint, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

    285 ft. - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    301 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

    301 ft. - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

Observations (33)

DistanceCodeObservation
3.6CM
276.1TFC
226.3TFC
266.5RFJ
123.1TFC
0AMH22 0299
14.2TFC
162.1TFC
285RFJ
302.5DAGS
58.8TFC
0MWL
2.1DAGS
250VC
73.9TFC
244.2CM
261.2TFC
94.8CC
301FM
173.1TFC
305.5MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
250MGP
211.6TFC
18.3CC
0MWM
99FL
108.5TFC
259.5RFJ
301RFJ
305.5AMH22 1351
23.8TFC
136.4FC
2MMC

Properties (6)

additional_info
SC318625
custom_field_two
3
customer
LACSD
datetime
2017-01-20T00:15:55-08:00
documentation
PRO PIPE
is_lateral_inspection
false