- Date
- 01/30/2017
- W/O
- 613619
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00424
- PipeID
- P06274
- Time
- 9:59 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4097
- Sewer Name
- 05 AVIATION BOULEVARD RELIEF TRUNK
- City
- HAWTHORNE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- WO_613619_TV05177_JAN2017
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 05 1039
- Downstream MH
- 05 1038
- Dir. of Survey
- Downstream
- Length Surveyed
- 30.5 ft.
- Total Length
- 30.5 ft.
- Structural Index
- 3
- Structural Quick
- 3500
- Structural Rating
- 15
- O&M Index
- 2
- O&M Quick
- 2511
- O&M Rating
- 11
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 26
Pipe schematic from manhole 05 1039 to 05 1038 Observation photos (2)

2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start