Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 11, 2017, 08:05 AM
  • 08 0485_08 0484 _11092017_010506.mp4

Date
09/11/2017
W/O
651771
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00019
PipeID
P00543
Time
1:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4868
Sewer Name
08 SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_651771_TV08165_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0485
Downstream MH
08 0484
Dir. of Survey
Downstream
Length Surveyed
220 ft.
Total Length
220 ft.
Structural Index
3
Structural Quick
413H
Structural Rating
136
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
136
Pipe schematic from manhole 08 0485 to 08 0484
MH: 08 0485MH: 08 0484downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04850 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area2.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start159.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"220 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish220 ft. AMH - Downstream Manhole, Survey Ends - 08 0484

Observation photos (3)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0AMH08 0485
2.1FM
2.1CM
0MWL
212.5TFC
220CM
220AMH08 0484
159.6TFC
0MWM
6CM

Properties (6)

additional_info
SC345927
custom_field_two
2
customer
LACSD
datetime
2017-09-11T01:05:02-07:00
documentation
PROPIPE
is_lateral_inspection
false