Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2017, 09:50 AM
  • 15 0366_15 0365 _12042017_025225.mp4

Date
04/12/2017
W/O
630214
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00598
PipeID
P12292
Time
2:50 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4460
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
18
Purpose
Routine Assessment
Project
WO_630214_TV15016_APR2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0366
Downstream MH
15 0365
Dir. of Survey
Downstream
Length Surveyed
256 ft.
Total Length
256 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
153
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
153
Pipe schematic from manhole 15 0366 to 15 0365
MH: 15 0366MH: 15 0365downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 15 03660 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start71.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"76.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"124.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"164.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"205.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"209.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"250.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"256 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish256 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK256 ft. AMH - Downstream Manhole, Survey Ends - 15 0365

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
76.1TFC
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
0AMH15 0366
250.2TFC
71.9TFC
164.7TFC
209.7TF
0MGOCONNECTION AT MH 9 O'CLOCK
256SAV
128.5TF
0MWM
205.7TFC
256MGOCONNECTION AT MH 9 O'CLOCK
256AMH15 0365
124.6TF
2.3SAV
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-04-12T02:50:52-07:00
documentation
PROPIPE
is_lateral_inspection
false