Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2017, 06:20 AM
  • B 0258_B 0257 _01052017_232034.mp4

Date
05/01/2017
W/O
630216
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00079
PipeID
P08737
Time
11:20 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4480
Sewer Name
B JOINT OUTFALL B - UNIT 1F
City
ROSEMEAD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
31
Purpose
Routine Assessment
Project
WO_630216_TV15042_APR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
B 0258
Downstream MH
B 0257
Dir. of Survey
Downstream
Length Surveyed
369 ft.
Total Length
369 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
28
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
29
Pipe schematic from manhole B 0258 to B 0257
MH: B 0258MH: B 0257downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 02580 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area25.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"90 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"158.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"159.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"202.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"202.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"241.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"243.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"261.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES282.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"293.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES311.4 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES312.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start339.5 ft. RFC - Roots Fine Connection, at 12 o'clock339.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"369 ft. AMH - Downstream Manhole, Survey Ends - B 0257369 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    261.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    293.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    311.4 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    312.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Connection, at 12 o'clock

    339.5 ft. - Roots Fine Connection, at 12 o'clock

Observations (21)

DistanceCodeObservation
293.4CL
241.5TFA
0AMHB 0258
0MWM
369AMHB 0257
159.7TFA
158.4TFA
90TF
106.8TFA
202.9TF
0MWL
311.4CL
339.5RFC
312.7CL
369CL
282.3TFA
25.4TFA
202.9TF
261.6CL
339.5TF
243.4TF