Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 25, 2017, 07:59 AM
  • 15 1166_15 1165 _20170525_021922.mp4

Date
05/25/2017
W/O
635526
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00635
PipeID
P25912
Time
12:59 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4531
Sewer Name
15 TYLER AVENUE RELIEF TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
17
Purpose
Routine Assessment
Project
WO_635526_TV15082_MAY2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 1165
Downstream MH
15 1166
Dir. of Survey
Upstream
Length Surveyed
306 ft.
Total Length
306 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
122
Pipe schematic from manhole 15 1165 to 15 1166
MH: 15 1165MH: 15 1166upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONNECTION AT 3 OC0 ft. AMH - Upstream Manhole, Survey Ends - 15 116640.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"107.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"178.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"302.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start306 ft. AMH - Downstream Manhole, Survey Begins - 15 1165306 ft. MWM - Water Mark, 20 %of cross sectional area306 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
306DAGS
265.5TF
0AMH15 1165
3.5DAGS
0MWM
198.3TF
0MWL
306MGOCONNECTION AT 3 OC
306AMH15 1166
127.5TFA

Properties (7)

additional_info
SC340745
custom_field_two
3
customer
LACSD
datetime
2017-05-25T00:59:18-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
39519