Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2017, 08:55 AM
  • B 1183_B 1182 _29062017_015640.mp4

Date
06/29/2017
W/O
640678
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01125
PipeID
P13503
Time
1:55 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4633
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
WO_640678_TV16072_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
B 1183
Downstream MH
B 1182
Dir. of Survey
Downstream
Length Surveyed
237.2 ft.
Total Length
237.2 ft.
Structural Index
2
Structural Quick
3223
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole B 1183 to B 1182
MH: B 1183MH: B 1182downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 11830 ft. MWL - Water Level, 10 %of cross sectional area23.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES67.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES143.3 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES162.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"174.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES227.9 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES237.2 ft. AMH - Downstream Manhole, Survey Ends - B 1182

Observation photos (5)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    23.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    67.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    143.3 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    174.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    227.9 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
23.1CL
143.3CM
0MWM
227.9CM
237.2AMHB 1182
0AMHB 1183
174.9CL
0MWL
162.4TFA
67.3CL

Properties (6)

additional_info
SC345350
custom_field_two
4
customer
LACSD
datetime
2017-06-29T01:55:50-07:00
documentation
PROPIPE
is_lateral_inspection
false