Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 16, 2017, 05:26 AM
  • 18 0897_18 0896 _20170515_225322.mpg

Date
05/15/2017
W/O
635479
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00709
PipeID
P14748
Time
10:26 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4497
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_635479_TV18051_MAY2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0897
Downstream MH
18 0896
Dir. of Survey
Downstream
Length Surveyed
475.8 ft.
Total Length
475.8 ft.
Structural Index
4
Structural Quick
5334
Structural Rating
27
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
27
Pipe schematic from manhole 18 0897 to 18 0896
MH: 18 0897MH: 18 0896downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - MAG COAT0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 089731 ft. SRV - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: YES31.4 ft. SAP - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO34.8 ft. SRV - Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: NO40.2 ft. SAP - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO, Start129.1 ft. SAP - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO, Finish218.5 ft. SRV - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO218.5 ft. SAP - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO284.1 ft. SAP - Surface Aggregate Projecting, from 08 to 10 o'clock, within 8 inches of joint: YES475.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0896

Observation photos (7)

  • Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: YES

    31 ft. - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO

    31.4 ft. - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: NO

    34.8 ft. - Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO, Start

    40.2 ft. - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO

    218.5 ft. - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO

    218.5 ft. - Surface Aggregate Projecting, from 03 to 04 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 08 to 10 o'clock, within 8 inches of joint: YES

    284.1 ft. - Surface Aggregate Projecting, from 08 to 10 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWL
31SRV
0MGOMAG COAT
0MWM
31.4SAP
218.5SRV
284.1SAP
218.5SAP
475.8AMH18 0896
34.8SRV
129.1SAP
0AMH18 0897
40.2SAP

Properties (6)

additional_info
SC345306
custom_field_two
2
customer
LACSD
datetime
2017-05-15T22:26:24-07:00
documentation
PROPIPE
is_lateral_inspection
false