Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2017, 09:32 AM
  • 08 0074_08 0073 _27122017_013606.mp4

Date
12/27/2017
W/O
679275
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00076
Time
1:32 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5296
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_679275_TV08116_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0074
Downstream MH
08 0073
Dir. of Survey
Downstream
Length Surveyed
13 ft.
Total Length
13 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 08 0074 to 08 0073
MH: 08 0074MH: 08 0073downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00740 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK, BLOCKED WITH GREASE2.2 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES13 ft. MSA - Survey Abandoned - cam blkd by rock

Observation photos (2)

  • Deposits Settled Other,  20 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES

    2.2 ft. - Deposits Settled Other, 20 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - cam blkd by rock

    13 ft. - Survey Abandoned - cam blkd by rock

Observations (6)

DistanceCodeObservation
0MWL
13MSAcam blkd by rock
0AMH08 0074
0MWM
2.2DSZ
0MGOCONNECTION AT MH 3 O'CLOCK, BLOCKED WITH GREASE

Properties (5)

additional_info
SC346770
custom_field_two
3
customer
LACSD
datetime
2017-12-27T01:32:17-08:00
is_lateral_inspection
false