Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 22, 2017, 09:06 AM
  • 08 0095_08 0094 _22122017_012459.mp4

Date
12/22/2017
W/O
679275
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00129
Time
1:06 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5291
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
01
Purpose
Routine Assessment
Project
WO_679275_TV08116_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0095
Downstream MH
08 0094
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
328.2 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
195
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
195
Pipe schematic from manhole 08 0095 to 08 0094
MH: 08 0095MH: 08 0094downstream0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 08 00950 ft. MWL - Water Level, 20 %of cross sectional area3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"166.4 ft. TSC - Tap Saddle Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"265.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"328.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK328.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0094328.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MGOCONNECTION AT MH 6 O'CLOCK
166.4TSC
3.6CM
0MGOCONNECTION AT MH 3 O'CLOCK
328.2MGOCONNECTION AT MH 9 O'CLOCK
64.6TF
328.2AMH08 0094
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
265.2TFC
0AMH08 0095
328.2CM
0MWL

Properties (5)

additional_info
SC346769
custom_field_two
3
customer
LACSD
datetime
2017-12-22T01:06:20-08:00
is_lateral_inspection
false