Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2016, 07:33 AM
  • 02 1582_02 1581_20160817_004042.mp4

Date
08/17/2016
W/O
585987
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00231
PipeID
P04033
Time
12:33 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3566
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_585987_TV02010_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1582
Downstream MH
02 1581
Dir. of Survey
Downstream
Length Surveyed
153.1 ft.
Total Length
153.2 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
84
O&M Index
2
O&M Quick
2E00
O&M Rating
58
Overall Index
2
Overall Quick
Overall Rating
142
Pipe schematic from manhole 02 1582 to 02 1581
MH: 02 1582MH: 02 1581downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 15820 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start3.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES11.3 ft. CM - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES20 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start21.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.8 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"148 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish148 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish153.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1581153.2 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    3.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    3.8 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    11.3 ft. - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    20 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
11.3CM
148DAGS
153.2AMH02 1581
0AMH02 1582
20CM
3.8DAGS
3.8CM
63.8TF
153.2MGOLATERAL AT MH 3 OCLOCK
0MWL
0MWM
148CM
21.6TF

Properties (6)

additional_info
SC305973
custom_field_two
3
customer
LACSD
datetime
2016-08-17T00:33:49-07:00
documentation
PRO PIPE
is_lateral_inspection
false