Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 16, 2016, 07:51 AM
  • 02 1595_02 1594_20160816_020728.mpg

Date
08/16/2016
W/O
585987
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00231
PipeID
P04050
Time
12:51 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3420
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_585987_TV02010_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1595
Downstream MH
02 1594
Dir. of Survey
Downstream
Length Surveyed
207 ft.
Total Length
207 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2G12
O&M Rating
84
Overall Index
2
Overall Quick
Overall Rating
87
Pipe schematic from manhole 02 1595 to 02 1594
MH: 02 1595MH: 02 1594downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 15950 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK0 ft. VC - Vermin Cockroach2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start4.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES8.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"11.1 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"43.3 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"58.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"103 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"132.8 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"168.8 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"180.4 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"207 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish207 ft. AMH - Downstream Manhole, Survey Ends - 02 1594207 ft. VC - Vermin Cockroach

Observation photos (10)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    4.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    8.2 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    11.1 ft. - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    43.3 ft. - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    58.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    103 ft. - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    132.8 ft. - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    168.8 ft. - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    180.4 ft. - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"

Observations (18)

DistanceCodeObservation
2DAGS
8.2TFC
103TFB
132.8TFB
0AMH02 1595
207DAGS
168.8TFB
43.3TFB
0MWM
0MWL
207AMH02 1594
4.2CM
58.1TFC
180.4TFB
11.1TFB
0MGOCONNECTION AT THE MH 9 O'CLOCK
207VC
0VC

Properties (6)

additional_info
SC305973
custom_field_two
4
customer
LACSD
datetime
2016-08-16T00:51:35-07:00
documentation
PRO PIPE
is_lateral_inspection
false