Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2016, 09:35 AM
  • B 1034_B 1033 _08222016_032034.mp4

Date
08/22/2016
W/O
585984
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00923
PipeID
P22477
Time
2:35 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3688
Sewer Name
B JOINT OUTFALL B - UNIT 1C REPLACEMENT
City
DOWNEY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Routine Assessment
Project
WO_585984_TV02129_AUG2016
Sewer Type
Gravity
Material
RGRCP-PTL
Shape
Circular
Height
66 in.
Width
66 in.
Upstream MH
B 1034
Downstream MH
B 1033
Dir. of Survey
Downstream
Length Surveyed
660.2 ft.
Total Length
660.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole B 1034 to B 1033
MH: B 1034MH: B 1033downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 10342 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start555.7 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"654.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Finish660.2 ft. AMH - Downstream Manhole, Survey Ends - B 1037

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start

Observations (7)

DistanceCodeObservation
660.2AMHB 1037
0MWL
654.1DAGS
555.7TBA
2DAGS
0MWM
0AMHB 1034

Properties (7)

additional_info
SC306018
custom_field_two
4
customer
LACSD
datetime
2016-08-22T02:35:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false
year_laid
36451