Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 19, 2016, 09:21 AM
  • H 1410_H 1409 _19082016_022136.mp4

Date
08/19/2016
W/O
585476
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01204
PipeID
P16281
Time
2:21 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3569
Sewer Name
H JOINT OUTFALL H - UNIT 8M
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
30
Purpose
Routine Assessment
Project
WO_585476_TV22034_AUG2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
H 1410
Downstream MH
H 1409
Dir. of Survey
Downstream
Length Surveyed
99.3 ft.
Total Length
99.4 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
42
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
42
Pipe schematic from manhole H 1410 to H 1409
MH: H 1410MH: H 1409downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 14100 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.1 ft. MGO - General Observation - MAG COAT 80%8.5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start25.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"77.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish99.4 ft. AMH - Downstream Manhole, Survey Ends - H 140999.4 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.5 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMHH 1410
99.4AMHH 1409
0MWM
25.2TFC
77.8SAV
99.4MGOLATERAL AT MH 9 OCLOCK
2.1MGOMAG COAT 80%
0MWL
8.5SAV

Properties (6)

additional_info
SC306153
custom_field_two
3
customer
LACSD
datetime
2016-08-19T02:21:06-07:00
documentation
PROPIPE
is_lateral_inspection
false