Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2016, 08:13 AM
  • B 1146_B 1145 _060216_011414.mp4

Date
06/02/2016
W/O
574365
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01125
PipeID
P13448
Time
1:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3388
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
WO_574365_TV16044_JUNE2016
Sewer Type
Gravity
Material
BRICK
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
B 1146
Downstream MH
B 1145
Dir. of Survey
Downstream
Length Surveyed
339.2 ft.
Total Length
339.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole B 1146 to B 1145
MH: B 1146MH: B 1145downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - B 11460 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area31.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"81.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"81.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"129.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"129.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"212 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"339.1 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK339.2 ft. AMH - Downstream Manhole, Survey Ends - B 1145

Observations (12)

DistanceCodeObservation
81.6TF
0MGOCONNECTION AT MH 9 OCLOCK
0AMHB 1146
31.7TFC
0MWM
212TF
339.2AMHB 1145
129.4TF
81.6TFC
339.1MGOCONNECTION AT MH 9 OCLOCK
129.4TF
0MWL

Properties (6)

additional_info
SC300388
custom_field_two
4
customer
LACSD
datetime
2016-06-02T01:13:24-07:00
documentation
PROPIPE
is_lateral_inspection
false