Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2016, 05:19 AM
  • B 1212_B 1211_060216_222531.mp4

Date
06/02/2016
W/O
574364
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01125
PipeID
P13532
Time
10:19 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3389
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
WO_574364_TV16042_JUNE2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
B 1212
Downstream MH
B 1211
Dir. of Survey
Downstream
Length Surveyed
226.5 ft.
Total Length
226.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole B 1212 to B 1211
MH: B 1212MH: B 1211downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 12122.3 ft. MGO - General Observation - 90% MAG148.4 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start226.4 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Finish226.5 ft. AMH - Downstream Manhole, Survey Ends - B 1211226.5 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK

Observation photos (1)

  • Deposits Settled Other,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: NO, Start

    148.4 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start

Observations (8)

DistanceCodeObservation
0MWL
148.4DSZ
2.3MGO90% MAG
226.5AMHB 1211
0MWM
0AMHB 1212
226.4DSZ
226.5MGOCONNECTION AT MH 9 OCLOCK

Properties (6)

additional_info
SC300389
custom_field_two
5
customer
LACSD
datetime
2016-06-02T22:19:43-07:00
documentation
PROPIPE
is_lateral_inspection
false