- Date
- 05/31/2016
- W/O
- 574295
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00570
- PipeID
- P18548
- Time
- 1:37 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3515
- Sewer Name
- 14 AVENUE "I" TRUNK
- City
- LANCASTER
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_574295_TV14045_JUNE2016
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 14 0267
- Downstream MH
- 14 0459
- Dir. of Survey
- Downstream
- Length Surveyed
- 147.7 ft.
- Total Length
- 147.7 ft.
- Structural Index
- 3
- Structural Quick
- 3D21
- Structural Rating
- 74
- O&M Index
- 2
- O&M Quick
- 2300
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 80
Pipe schematic from manhole 14 0267 to 14 0459 Observation photos (5)

16.5 ft. - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

22 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

25.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

143.6 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES

147.7 ft. - General Observation - COCKROACHES IN MANHOLE