Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 16, 2016, 05:03 AM
  • 05 1657_05 1655 _061516_220349.mpg

Date
06/15/2016
W/O
563399
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P07575
Time
10:03 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3398
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
WO_563399_TV05132_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1657
Downstream MH
05 1655
Dir. of Survey
Downstream
Length Surveyed
546.7 ft.
Total Length
546.7 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 05 1657 to 05 1655
MH: 05 1657MH: 05 1655downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 16570 ft. MWL - Water Level, 40 %of cross sectional area2.4 ft. CS - Crack Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES6.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES10.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start35.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"174.8 ft. MGO - General Observation - ABANDONED MH247.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"263.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"269.3 ft. RPZ - Repair Other, within 8 inches of joint: YES - HOLE W/ REPAIR323.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"436.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"541.2 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish546.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK546.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1655

Observation photos (5)

  • Crack Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES

    2.4 ft. - Crack Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    6.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    10.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ABANDONED MH

    174.8 ft. - General Observation - ABANDONED MH

  • Repair Other, within 8 inches of joint: YES - HOLE W/ REPAIR

    269.3 ft. - Repair Other, within 8 inches of joint: YES - HOLE W/ REPAIR

Observations (16)

DistanceCodeObservation
546.3MGOCONNECTION AT THE MH 9 O'CLOCK
2.4CS
323.8TFC
263.8TFA
174.8MGOABANDONED MH
436.6TF
269.3RPZHOLE W/ REPAIR
0MWM
247.9TFC
6.4CL
541.2CM
0AMH05 1657
35.8TFC
10.5CM
0MWL
546.7AMH05 1655

Properties (6)

additional_info
SC300398
custom_field_two
3
customer
LACSD
datetime
2016-06-15T22:03:19-07:00
documentation
PROPIPE
is_lateral_inspection
false