Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2016, 08:50 AM
  • 05 1655_05 1654 _062016_015135.mpg

Date
06/20/2016
W/O
563399
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06878
Time
1:50 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3399
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
30
Purpose
Routine Assessment
Project
WO_563399_TV05132_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1654
Downstream MH
05 1655
Dir. of Survey
Upstream
Length Surveyed
297 ft.
Total Length
297 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
171
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
171
Pipe schematic from manhole 05 1654 to 05 1655
MH: 05 1654MH: 05 1655upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 16550 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK106.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"154.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"197.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"241.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"283.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"287.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start297 ft. MWM - Water Mark, 30 %of cross sectional area297 ft. AMH - Downstream Manhole, Survey Begins - 05 1654297 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
9.6CM
142.8TFC
13.6TF
55.5TFC
297MGOCONNECTION AT THE MH 9 O'CLOCK
0MWM
99.1TFA
297AMH05 1655
190.6TF
0AMH05 1654
297CM
297MGOCONNECTION AT THE MH 3 O'CLOCK
0MWL

Properties (6)

additional_info
SC300399
custom_field_two
3
customer
LACSD
datetime
2016-06-20T01:50:57-07:00
documentation
PROPIPE
is_lateral_inspection
false