Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2017, 05:32 AM
Date
08/24/2017
W/O
651582
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00707
PipeID
P14693
Time
10:32 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4699
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_651582_TV18113_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0829
Downstream MH
18 0828A
Dir. of Survey
Downstream
Length Surveyed
255.8 ft.
Total Length
255.8 ft.
Structural Index
4
Structural Quick
4G31
Structural Rating
159
O&M Index
2
O&M Quick
2I00
O&M Rating
102
Overall Index
3
Overall Quick
Overall Rating
261
Pipe schematic from manhole 18 0829 to 18 0828A
MH: 18 0829MH: 18 0828Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08290.3 ft. MWM - Water Mark, 15 %of cross sectional area3.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.3 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start63.3 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start63.3 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish110.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"112.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"155.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"158.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"188.8 ft. RPP - Repair Patch, from 09 to 03 o'clock, within 8 inches of joint: YES - VCP201.6 ft. MGO - General Observation - MH 18 0828A NO LONGER EXISTS204.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"207.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"253.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"255.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"255.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0828A255.8 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish255.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    63.3 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Repair Patch, from 09 to 03 o'clock, within 8 inches of joint: YES - VCP

    188.8 ft. - Repair Patch, from 09 to 03 o'clock, within 8 inches of joint: YES - VCP

Observations (20)

DistanceCodeObservation
255.8TFC
255.8AMH18 0828A
63.3FM
155.8TFC
255.8FM
188.8RPPVCP
3.3CM
63.3CM
0.3MWM
112.8TFC
253.4TF
3.2DAGS
0MWL
201.6MGOMH 18 0828A NO LONGER EXISTS
204.9TFC
158.5TFC
0AMH18 0829
110.2TFC
255.8DAGS
207.1TFC

Properties (6)

additional_info
SC345638
custom_field_two
3
customer
LACSD
datetime
2017-08-24T22:32:40-07:00
documentation
PROPIPE
is_lateral_inspection
false