Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 1, 2017, 05:58 AM
  • H 0353A_H 0340 _20170801_001329.mp4

Date
07/31/2017
W/O
646405
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00175
PipeID
P10791
Time
10:58 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4674
Sewer Name
H JOINT OUTFALL H - UNIT 4
City
PICO RIVERA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
19A
Purpose
Routine Assessment
Project
WO_646405_TV02200_JUL2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Width
63 in.
Upstream MH
H 0353A
Downstream MH
H 0340
Dir. of Survey
Downstream
Length Surveyed
85.5 ft.
Total Length
85.5 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
48
O&M Index
2
O&M Quick
412B
O&M Rating
36
Overall Index
3
Overall Quick
Overall Rating
84
Pipe schematic from manhole H 0353A to H 0340
MH: H 0353AMH: H 0340downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 0353A5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start85.5 ft. AMH - Downstream Manhole, Survey Ends - H 034085.5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish85.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
5SAV
85.5AMHH 0340
85.5SAV
0MWL
0MWM
5DAGS
85.5DAGS
0AMHH 0353A

Properties (6)

additional_info
SC345612
custom_field_two
3
customer
LACSD
datetime
2017-07-31T22:58:04-07:00
documentation
PROPIPE
is_lateral_inspection
false