Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2017, 11:51 AM
  • F 0288_F 0287 _01092017_040535.mp4

Date
01/09/2017
W/O
613620
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00931
PipeID
P20327
Time
3:51 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4118
Sewer Name
F JOINT OUTFALL F - UNIT 5 RELIEF
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
34
Purpose
Routine Assessment
Project
WO_613620_TV02234_JAN2017
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
F 0287
Downstream MH
F 0288
Dir. of Survey
Upstream
Length Surveyed
49.9 ft.
Total Length
49.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
2
Overall Quick
Overall Rating
20
Pipe schematic from manhole F 0287 to F 0288
MH: F 0287MH: F 0288upstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG OF D/S SIPHON.0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish47.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start49.9 ft. MWM - Water Mark, 25 %of cross sectional area49.9 ft. AMH - Downstream Manhole, Survey Begins - F 028749.9 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF THE UPLEG OF D/S SIPHON.

    49.9 ft. - Survey Abandoned - VIEW OF THE UPLEG OF D/S SIPHON.

Observations (6)

DistanceCodeObservation
0MWM
49.9MSAVIEW OF THE UPLEG OF D/S SIPHON.
0AMHF 0287
49.9DAGS
2DAGS
0MWL

Properties (7)

additional_info
SC306705
custom_field_two
4
customer
LACSD
datetime
2017-01-09T03:51:35-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
32789