Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2016, 11:22 AM
  • 05 1001_05 1000 _12272016_035506.mp4

Date
12/27/2016
W/O
613357
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00421
PipeID
P06233
Time
3:22 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3949
Sewer Name
05 AVIATION BOULEVARD TRUNK
City
HAWTHORNE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
WO_613357_TV05010_JAN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1001
Downstream MH
05 1000
Dir. of Survey
Downstream
Length Surveyed
332.1 ft.
Total Length
332.1 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2L11
O&M Rating
131
Overall Index
2
Overall Quick
Overall Rating
137
Pipe schematic from manhole 05 1001 to 05 1000
MH: 05 1001MH: 05 1000downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 10010 ft. MWL - Water Level, 5 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 10 %of cross sectional area3.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start27.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"68.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO102.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"181.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"184.7 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES255.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"328.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish332.1 ft. AMH - Downstream Manhole, Survey Ends - 05 1000

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO

    68.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    184.7 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
27.8TFC
0AMH05 1001
0MWL
181.2TFC
328.8DAGS
332.1AMH05 1000
102.6TFC
68.6CM
184.7CM
255.5TFC
0VC
0MWM
3.5DAGS

Properties (6)

additional_info
SC317697
custom_field_two
4
customer
LACSD
datetime
2016-12-27T03:22:18-08:00
documentation
PRO-PIPE
is_lateral_inspection
false