Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2016, 12:45 PM
  • 05 1006_05 1005 _12272016_045816.mp4

Date
12/27/2016
W/O
613357
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00421
PipeID
P06238
Time
4:45 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3949
Sewer Name
05 AVIATION BOULEVARD TRUNK
City
HAWTHORNE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
WO_613357_TV05010_JAN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1005
Downstream MH
05 1006
Dir. of Survey
Upstream
Length Surveyed
335.2 ft.
Total Length
335.2 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 1005 to 05 1006
MH: 05 1005MH: 05 1006upstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 10060 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK57.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"59.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish63.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES134.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"210.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"283.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"335.2 ft. MWM - Water Mark, 10 %of cross sectional area335.2 ft. MWL - Water Level, 5 %of cross sectional area335.2 ft. AMH - Downstream Manhole, Survey Begins - 05 1005335.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    271.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
51.9TFC
335.2MGOCONNECTION AT MH 3 O'CLOCK
124.4TFA
335.2AMH05 1006
275.3FM
201TFC
0MWM
0MWL
277.4TFC
0AMH05 1005
271.3FM
335.2MGOCONNECTION AT MH 9 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK

Properties (6)

additional_info
SC317697
custom_field_two
3
customer
LACSD
datetime
2016-12-27T04:45:03-08:00
documentation
PRO-PIPE
is_lateral_inspection
false