Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2016, 06:48 AM
  • 03 0584_03 0400 _12272016_230334.mp4

Date
12/27/2016
W/O
613343
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00371
PipeID
P04976
Time
10:48 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3901
Sewer Name
03 MARINA TRUNK, SECTION 2
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
25
Purpose
Routine Assessment
Project
WO_613343_TV03019_JAN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
03 0400
Downstream MH
03 0584
Dir. of Survey
Upstream
Length Surveyed
248.1 ft.
Total Length
248.2 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
10
O&M Index
2
O&M Quick
2I00
O&M Rating
98
Overall Index
2
Overall Quick
Overall Rating
108
Pipe schematic from manhole 03 0400 to 03 0584
MH: 03 0400MH: 03 0584upstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 03 05941.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish25.4 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES76.9 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES97.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES234.6 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES246.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start248.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE248.2 ft. MWM - Water Mark, 10 %of cross sectional area248.2 ft. MWL - Water Level, 5 %of cross sectional area248.2 ft. AMH - Downstream Manhole, Survey Begins - 03 0400

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    13.6 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    150.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    171.3 ft. - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    222.8 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
150.8CM
2.1DAGS
0MWM
0.1MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0MWL
0AMH03 0400
171.3CC
222.8FM
248.2MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
13.6FC
246.5DAGS
248.2AMH03 0594

Properties (6)

additional_info
SC305242
custom_field_two
2
customer
LACSD
datetime
2016-12-27T22:48:49-08:00
documentation
PRO PIPE
is_lateral_inspection
false