Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2017, 05:16 AM
  • 15 0608_15 0607A_12102017_222018.mp4

Date
10/12/2017
W/O
663065
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00601
PipeID
P26432
Time
10:16 PM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4829
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_663065_TV15183_OCT2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
15 0608
Downstream MH
15 0607A
Dir. of Survey
Downstream
Length Surveyed
146.6 ft.
Total Length
146.6 ft.
Structural Index
4
Structural Quick
4232
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole 15 0608 to 15 0607A
MH: 15 0608MH: 15 0607Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 06086.9 ft. FM - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES14.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"50.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"98.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"104.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"105.5 ft. FM - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES120.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES123.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"135.5 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES146.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0607A146.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    6.9 ft. - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    105.5 ft. - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    120.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    135.5 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
146.6AMH15 0607A
50.2TF
105.5FM
146.6MGOCONNECTION AT MH 3 O'CLOCK
6.9FM
98.4TF
123.4TF
14.3TF
0MWL
104.2TFC
0MWM
120.9CM
135.5CM
0AMH15 0608

Properties (6)

additional_info
SC353080
custom_field_two
4
customer
LACSD
datetime
2017-10-12T22:16:30-07:00
documentation
PRO-PIPE
is_lateral_inspection
false