Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 12, 2017, 08:34 AM
  • 15 0605_15 0604_12102017_013446.mp4

Date
10/12/2017
W/O
663065
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00601
PipeID
P12537
Time
1:34 AM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4828
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_663065_TV15183_OCT2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0605
Downstream MH
15 0604
Dir. of Survey
Downstream
Length Surveyed
308.7 ft.
Total Length
308.7 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 15 0605 to 15 0604
MH: 15 0605MH: 15 0604downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 060533.6 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES63.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES68.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"80.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"128.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"170.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"194 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"244.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"256.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"262.4 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"299.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES308.7 ft. AMH - Downstream Manhole, Survey Ends - 15 0604

Observation photos (3)

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    33.6 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    63.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    299.3 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
170.3TFC
128.3TF
33.6FL
308.7AMH15 0604
256.2TF
0MGOCONNECTION AT MH 9 O'CLOCK
63.7FM
68.6TFC
194TF
80.5TFC
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
262.4TB
0MWL
0AMH15 0605
299.3FL
244.5TB

Properties (6)

additional_info
SC353079
custom_field_two
3
customer
LACSD
datetime
2017-10-12T01:34:27-07:00
documentation
PRO-PIPE
is_lateral_inspection
false