Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2016, 06:04 AM
  • 15 0225_15 0224_10052016_230637.mp4

Date
05/10/2016
W/O
568733
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00627
PipeID
P12147
Time
11:04 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3346
Sewer Name
15 SAN JOSE CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_568733_TV15133_MAY2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
15 0225
Downstream MH
15 0224
Dir. of Survey
Downstream
Length Surveyed
167.4 ft.
Total Length
167.4 ft.
Structural Index
3
Structural Quick
3F2F
Structural Rating
165
O&M Index
2
O&M Quick
2I00
O&M Rating
102
Overall Index
2
Overall Quick
Overall Rating
267
Pipe schematic from manhole 15 0225 to 15 0224
MH: 15 0225MH: 15 0224downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 02250 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start75.5 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start166.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish166.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE166.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish166.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish166.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish167.4 ft. AMH - Downstream Manhole, Survey Ends - 15 0224167.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK167.4 ft. MGO - General Observation - CAPPED CONNECTION AT MH 3 O'CLOCK

Observations (15)

DistanceCodeObservation
2SAV
2SSS
166.1SSS
0MWL
166.1MGOCOCKROACHES IN MANHOLE
2DAGS
0AMH15 0225
0MWM
166.1SAV
167.4AMH15 0224
167.4MGOACTIVE CONNECTION AT MH 9 O'CLOCK
167.4MGOCAPPED CONNECTION AT MH 3 O'CLOCK
166.1DSZ
166.1DAGS
75.5DSZ

Properties (6)

additional_info
SC305625
custom_field_two
3
customer
LACSD
datetime
2016-05-10T23:04:43-07:00
documentation
PRO PIPE
is_lateral_inspection
false