Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 21, 2017, 07:16 AM
  • 02 0019_02 0018_7212017_044630.mp4

Date
07/21/2017
W/O
0641143
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00234
PipeID
P03047
Time
12:16 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0599
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Capital Improvement Program Assesment
Project
20170721VMR_ARTESIA_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0018
Downstream MH
02 0019
Dir. of Survey
Upstream
Length Surveyed
323.3 ft.
Total Length
323.3 ft.
Structural Index
2
Structural Quick
3124
Structural Rating
15
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
21
Pipe schematic from manhole 02 0018 to 02 0019
MH: 02 0018MH: 02 0019upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05:27 AM0.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"0.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"77.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: YES77.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"79.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, at 03 o'clock, , within 8 inches of joint: NO79.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES79.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4"150.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES158.2 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES164.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES164.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES186.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"188.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4"214.5 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES229.3 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES271.4 ft. CC - Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES281.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"283 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES284.2 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"285.6 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: YES323.3 ft. AMH - Downstream Manhole, Survey Begins - 04:54 AM323.3 ft. MWL - Water Level, 20 %of cross sectional area323.3 ft. MWM - Water Mark, 40 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 10 %of cross sectional area, at 09 o'clock,  , within 8 inches of joint: YES

    37.7 ft. - Deposits Attached Grease, 10 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Grease, 10 %of cross sectional area, at 03 o'clock,  , within 8 inches of joint: NO

    244.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, at 03 o'clock, , within 8 inches of joint: NO

Observations (24)

DistanceCodeObservation
134.6TF
323.3AMH05:27 AM
39.1TFA
0AMH04:54 AM
94CC
323.2TFC
244CL
244.1DAGS
172.4CL
41.6TF
159.2CL
0MWL
245.9DAGS
40.3CC
37.7DAGS
108.8CC
51.9CC
137.1TF
323.2TFC
165.1CM
245.9TFA
244TF
0MWM
158.8CL

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2017-07-21T00:16:00-07:00
is_lateral_inspection
false