Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 1, 2019, 07:33 AM
  • B 1097_B 1096 _05012019_011645.mp4

Date
05/01/2019
W/O
761338
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01124
PipeID
P13722
Time
12:33 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6526
Sewer Name
B JOINT OUTFALL B - UNIT 6G
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_761338_TV02344_APR2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
B 1097
Downstream MH
B 1096
Dir. of Survey
Downstream
Length Surveyed
863 ft.
Total Length
863 ft.
Structural Index
3
Structural Quick
3a00
Structural Rating
507
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
511
Pipe schematic from manhole B 1097 to B 1096
MH: B 1097MH: B 1096downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK0 ft. MWM - Water Mark, 65 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 109715 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start15 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE216.2 ft. MGO - General Observation - POSSIBLE BULKHEAD @ 02 O'CLOCK216.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 15"327.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"615.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"640.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"643.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 15"732.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 15"814.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"828 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"859.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish863 ft. AMH - Downstream Manhole, Survey Ends - B 1096

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
15SAP
0MWL
0MGOCONNECTION IN MH 3 OCLOCK
15MGOMAG COAT THROUGHOUT PIPE
0MWM
0AMHB 1097
859.2SAP
615.8TF
828TFA
216.2MGOPOSSIBLE BULKHEAD @ 02 O'CLOCK
863AMHB 1096
732.4TFC
814.1TF
640.9TF
216.2TFC
643.9TFC
327.9TFA

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-05-01T00:33:45-07:00
documentation
PROPIPE
is_lateral_inspection
false