Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2018, 09:30 AM
  • 05 0816_05 0815 _09112018_013122.mp4

Date
11/09/2018
W/O
735499
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00419
PipeID
P06046
Time
1:30 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6215
Sewer Name
05 ARLINGTON AVENUE EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_735499_TV05345_NOV2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 0816
Downstream MH
05 0815
Dir. of Survey
Downstream
Length Surveyed
336.9 ft.
Total Length
336.9 ft.
Structural Index
2
Structural Quick
312L
Structural Rating
137
O&M Index
2
O&M Quick
4113
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole 05 0816 to 05 0815
MH: 05 0816MH: 05 0815downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 08160 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"42.3 ft. RFL - Roots Fine Lateral, at 02 o'clock42.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"89.3 ft. RFL - Roots Fine Lateral, at 10 o'clock89.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"92.1 ft. RFL - Roots Fine Lateral, at 02 o'clock142.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"145.7 ft. RBL - Roots Ball Lateral, at 02 o'clock, 75 %145.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"195.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"242.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"292.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"295.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"335 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH 5% LESS335 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.9 ft. AMH - Downstream Manhole, Survey Ends - 05 0815

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
42.3RFL
0MWL
145.7RBL
92.1TF
335MGOGREASE THROUGHOUT THE REACH 5% LESS
89.3RFL
336.9CM
335SSS
2SSS
292.6TF
0AMH05 0816
145.7TF
92.1RFL
0MWM
42.3TF
245.4TFC
295.4TF
192.7TF
142.8TF
336.9AMH05 0815
5.6CM
242.6TF
39.6TFC
89.3TF
195.3TFC

Properties (6)

additional_info
SC364243
custom_field_two
3
customer
LACSD
datetime
2018-11-09T01:30:59-08:00
documentation
PROPIPE
is_lateral_inspection
false