Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2019, 12:42 PM
  • 32 1002A_32 1286 _01282019_050159.mp4

Date
01/28/2019
W/O
745464
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19448
Time
4:42 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6368
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_745464_TV32053_JAN2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1002A
Downstream MH
32 1286
Dir. of Survey
Downstream
Length Surveyed
223.9 ft.
Total Length
223.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
412H
O&M Rating
92
Overall Index
2
Overall Quick
Overall Rating
95
Pipe schematic from manhole 32 1002A to 32 1286
MH: 32 1002AMH: 32 1286downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CAPPED CONNECTION @ U/S MH - 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 32 1002A0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start223.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish223.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish223.9 ft. AMH - Downstream Manhole, Survey Ends - 32 1286223.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
2DAGS
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
223.9DAGS
223.9SAP
0MGOCAPPED CONNECTION @ U/S MH - 9 O'CLOCK
0AMH32 1002A
2.2SAP
223.9AMH32 1286
0MWM
0MWL
223.9MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK

Properties (5)

additional_info
SC365685
custom_field_two
2
customer
LACSD
datetime
2019-01-28T04:42:52-08:00
is_lateral_inspection
false