Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2016, 08:29 AM
  • 32 1212_32 1211_13042016_013026.mp4

Date
04/13/2016
W/O
563392
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00843
PipeID
P19666
Time
1:29 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3315
Sewer Name
32 SOLEDAD CANYON RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
05
Purpose
Routine Assessment
Project
WO_563392_TV32023_APRIL2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
32 1212
Downstream MH
32 1211
Dir. of Survey
Downstream
Length Surveyed
604.8 ft.
Total Length
604.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412W
O&M Rating
244
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole 32 1212 to 32 1211
MH: 32 1212MH: 32 1211downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 12120 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.5 ft. MGO - General Observation - MAG COATING 85%157.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"602.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish604.8 ft. AMH - Downstream Manhole, Survey Ends - 32 1211

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.5MGOMAG COATING 85%
602.5DAGS
0MWL
2DAGS
0AMH32 1212
0MWM
157.2TBA
604.8AMH32 1211

Properties (6)

additional_info
SC305442
custom_field_two
4
customer
LACSD
datetime
2016-04-13T01:29:48-07:00
is_lateral_inspection
false
year_laid
19730503