Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 28, 2019, 11:30 AM
  • B 0283_B 0282 _02282019_033110.mp4

Date
02/28/2019
W/O
750814
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00082
PipeID
P08773
Time
3:30 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6411
Sewer Name
B JOINT OUTFALL B - UNIT 1H
City
ROSEMEAD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_750814_TV15119_FEB2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
B 0283
Downstream MH
B 0282
Dir. of Survey
Downstream
Length Surveyed
457.5 ft.
Total Length
457.5 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
54
O&M Index
2
O&M Quick
412Q
O&M Rating
186
Overall Index
2
Overall Quick
Overall Rating
240
Pipe schematic from manhole B 0283 to B 0282
MH: B 0283MH: B 0282downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 02830 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start39.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start130.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish455.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish457 ft. MGO - General Observation - COCKROACHES - D/S MH457.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK457.5 ft. AMH - Downstream Manhole, Survey Ends - B 0282

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    39.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
457MGOCOCKROACHES - D/S MH
457.5MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWL
39.2CM
0AMHB 0283
0MWM
457.5AMHB 0282
455.8DAGS
130.2CM
2DAGS

Properties (6)

additional_info
SC365926
custom_field_two
3
customer
LACSD
datetime
2019-02-28T03:30:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false