Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2018, 07:57 AM
  • 18 0750A_18 0750_09052018_010534.mp4

Date
05/09/2018
W/O
701388
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00706
PipeID
P14604
Time
12:57 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5315
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_701388_TV18103_MAY2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0750A
Downstream MH
18 0750
Dir. of Survey
Downstream
Length Surveyed
205 ft.
Total Length
205 ft.
Structural Index
5
Structural Quick
5200
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
10
Pipe schematic from manhole 18 0750A to 18 0750
MH: 18 0750AMH: 18 0750downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 0750A0 ft. MWL - Water Level, 40 %of cross sectional area9.9 ft. MGO - General Observation - MAGNEZIUM H.O COATING start9.9 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start33.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish33.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start202.8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish202.9 ft. MGO - General Observation - MAGNEZIUM H.O COATING finish205 ft. AMH - Downstream Manhole, Survey Ends - 18 0750

Observation photos (2)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9.9 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    33.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
202.8SRC
0MWM
202.9MGOMAGNEZIUM H.O COATING finish
9.9MGOMAGNEZIUM H.O COATING start
33.2SRV
205AMH18 0750
9.9SRV
33.2SRC
0AMH18 0750A
0MWL

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2018-05-09T00:57:04-07:00
is_lateral_inspection
false