- Date
- 05/08/2018
- W/O
- 701119
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00349
- PipeID
- P02969
- Time
- 2:26 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5660
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- BELL GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- WO_701119_TV02220_MAY2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- 02 1398
- Downstream MH
- 02 1397
- Dir. of Survey
- Downstream
- Length Surveyed
- 418.1 ft.
- Total Length
- 418.1 ft.
- Structural Index
- 3
- Structural Quick
- 513P
- Structural Rating
- 254
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 254
Pipe schematic from manhole 02 1398 to 02 1397 Observation photos (2)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

76.4 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO