Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 8, 2018, 10:20 AM
  • 02 1397_02 1396_08052018_033852.mp4

Date
05/08/2018
W/O
701119
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02968
Time
3:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5660
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
WO_701119_TV02220_MAY2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
02 1397
Downstream MH
02 1396
Dir. of Survey
Downstream
Length Surveyed
441.8 ft.
Total Length
441.8 ft.
Structural Index
3
Structural Quick
543O
Structural Rating
266
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
266
Pipe schematic from manhole 02 1397 to 02 1396
MH: 02 1397MH: 02 1396downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13978.6 ft. MGO - General Observation - MAG COAT31.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start68.2 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO118.6 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO196.7 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO334.8 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO440.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish441.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1396

Observation photos (5)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    31.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

    68.2 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO

    118.6 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO

    196.7 ft. - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO

    334.8 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO

Observations (11)

DistanceCodeObservation
334.8SRV
68.2SRV
0MWL
0MWM
196.7SRV
441.8AMH02 1396
31.4SAP
440.8SAP
0AMH02 1397
118.6SRV
8.6MGOMAG COAT

Properties (5)

additional_info
SC359316
custom_field_two
2
customer
LACSD
datetime
2018-05-08T03:20:00-07:00
is_lateral_inspection
false