Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2018, 08:42 AM
  • 02 1400_02 1399_09052018_015803.mp4

Date
05/09/2018
W/O
701119
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02971
Time
1:42 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5661
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
WO_701119_TV02220_MAY2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
02 1400
Downstream MH
02 1399
Dir. of Survey
Downstream
Length Surveyed
450.3 ft.
Total Length
450.3 ft.
Structural Index
4
Structural Quick
5Q3Q
Structural Rating
712
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
712
Pipe schematic from manhole 02 1400 to 02 1399
MH: 02 1400MH: 02 1399downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 14000 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2 ft. MGO - General Observation - 95% MAG COAT INTACT4.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.9 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORATIC127 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"254.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"356.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"365.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"450.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1399450.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish450.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORATIC

    6.9 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORATIC

Observations (15)

DistanceCodeObservation
127TF
2MGO95% MAG COAT INTACT
0MWM
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK
254.3TF
6.9SRVSPORATIC
450.3AMH02 1399
0AMH02 1400
4.2SAP
0MGOCONNECTION AT MH 3 O'CLOCK
450.3SAP
356.7TF
450.3SRV
365.8TF

Properties (5)

additional_info
SC359317
custom_field_two
2
customer
LACSD
datetime
2018-05-09T01:42:24-07:00
is_lateral_inspection
false