- Date
- 05/18/2018
- W/O
- 695800
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00782
- PipeID
- P16201
- Time
- 1:21 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5599
- Sewer Name
- 21 POMONA W.R.P. INFLUENT SEWER #2
- City
- POMONA
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- WO_695800_TV21089_APR2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Width
- 42 in.
- Upstream MH
- 21 1077
- Downstream MH
- 21 1076
- Dir. of Survey
- Downstream
- Length Surveyed
- 83.2 ft.
- Total Length
- 83.2 ft.
- Structural Index
- 3
- Structural Quick
- 3B00
- Structural Rating
- 48
- O&M Index
- 3
- O&M Quick
- 413A
- O&M Rating
- 37
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 85
Pipe schematic from manhole 21 1077 to 21 1076 Observation photos (2)

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

29.1 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS