Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2018, 07:24 AM
  • 08 0062_08 0061 _12042018_003457.mp4

Date
04/12/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00064
Time
12:24 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5528
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0062
Downstream MH
08 0061
Dir. of Survey
Downstream
Length Surveyed
297.6 ft.
Total Length
297.7 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
177
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
178
Pipe schematic from manhole 08 0062 to 08 0061
MH: 08 0062MH: 08 0061downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00620 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area3.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start36 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"36.4 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES86.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"134.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"238.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"249.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"271.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"297.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK297.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0061297.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

    36.4 ft. - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
0AMH08 0062
297.7MGOCONNECTION AT MH 3 O'CLOCK
297.7AMH08 0061
271.9TFC
0MWL
0MWM
297.7CM
238.1TFC
134.9TFC
3.7CM
36TF
36.4RFJ
249.5TF
86.5TFC
185.9TF

Properties (6)

additional_info
SC358735
custom_field_two
3
customer
LACSD
datetime
2018-04-12T00:24:12-07:00
documentation
PROPIPE
is_lateral_inspection
false